Key Features
- Viscosity measurement of solutions and liquids
- A functional device that meets the basic needs of every textile laboratory, with regular and flexible operation
- Viscosity range of 10 to 100,000 cP
- Rotor speed selectable at 6, 12, 30 or 60 rpm
- Reports apparent viscosity at a specified temperature and speed (mPa·s)
- Measuring geometry, spindle, speed and temperature are selected for the method
- Verified with a certified viscosity fluid and temperature
- Compact: approx. 350 × 400 × 600 mm and 5–12 kg net; one-year manufacturer warranty
About the TLI TXL-GEN-010 Viscometer
The TXL-GEN-010 is a viscometer from TexLab Instruments (TLI), Turkey, for the viscosity measurement of solutions and liquids. TLI describes it as a functional device that meets the basic needs of every textile laboratory, offering regular and flexible operation capabilities.
The viscosity range is 10 to 100,000 cP and the rotor speed can be selected as 6, 12, 30 or 60 rpm. The measured output is the apparent viscosity at a specified temperature and speed, in mPa·s. For each test the measuring geometry, spindle, speed and temperature are selected to suit the method.
The instrument is verified with a certified viscosity fluid and temperature. Records link the method code and edition, specimen ID, operator and selected test parameters, and the raw measurements, units, valid / invalid test flags and reported result stay traceable.
TLI TXL-GEN-010 specifications
| Model | TXL-GEN-010, viscometer |
|---|---|
| Manufacturer | TexLab Instruments (TLI), Turkey |
| Application | Viscosity measurement of solutions and liquids |
| Viscosity range | 10 to 100,000 cP |
| Rotor speeds | 6, 12, 30 or 60 rpm (selectable) |
| Measured output | Apparent viscosity at a specified temperature and speed (mPa·s) |
| Parameters selected for the method | Measuring geometry, spindle, speed and temperature |
| Verification points | Certified viscosity fluid and temperature |
| Warranty | One (1) year manufacturer warranty |
Installation data (approximate)
| Electrical supply | Approx. 220–240 V AC, 50/60 Hz, single phase; build-dependent |
|---|---|
| Connected load | Approx. 15–50 W |
| Dimensions (W × D × H) | Approx. 350 × 400 × 600 mm |
| Net weight | Approx. 5–12 kg |
| Gross / shipping weight | Approx. 15.5–25 kg (estimated packing allowance) |
| Lab requirements | Level, stable working surface; specimen conditioning follows the selected method |
Approximate rows are preliminary engineering estimates based on comparable equipment and function / capacity. They are not verified manufacturing measurements or standard requirements; installation and shipment are finalised against the approved drawing and nameplate. Estimate scope: base product, one unit; external computer, bench and auxiliary plant excluded.
Specifications are as published by the manufacturer, TLI, and are approximate and subject to change without prior notice for continuous design improvements. Download the product brochure or contact us to confirm the configuration for your laboratory.
Records and traceability
Linked records
Method code and edition, specimen ID, operator and the selected test parameters are linked to the record.
Method-defined calculation
The calculation and endpoint are defined by the selected method edition; instrument signals and operator assessments are kept distinct.
Traceable results
Raw measurements, units, valid / invalid test flags and the reported result remain traceable.
Checked calculations
Calculations are checked against known inputs and an independent calculation; sensor channels are checked against calibration values.
Method-specific software and recording requirements apply, and the delivered software modules are defined by the order scope. The TLI brochure lists no specific test methods; suitability is established by assessing hardware, method edition and calibration together.
Viscometer: frequently asked questions
What does the TLI TXL-GEN-010 measure?
It measures the viscosity of solutions and liquids. The measured output is the apparent viscosity at a specified temperature and speed, in mPa·s.
What viscosity range and speeds does it cover?
The viscosity range is 10 to 100,000 cP (equal to 10 to 100,000 mPa·s) and the rotor speed can be selected as 6, 12, 30 or 60 rpm.
Which parameters are set for a test?
The measuring geometry, spindle, speed and temperature are selected for the method being applied.
How is the viscometer verified?
Verification uses a certified viscosity fluid and temperature. Calculations are checked against known inputs and an independent calculation, and sensor channels against calibration values.
Which test methods does it cover?
The TLI brochure lists no specific test methods. Suitability for a method is established by assessing the hardware, the method edition and the calibration together, so tell us the method you apply and we will confirm the configuration.
What are the installation requirements?
Approximately 220–240 V AC, 50/60 Hz, single phase, with an approx. 15–50 W connected load. Dimensions are approx. 350 × 400 × 600 mm (W × D × H), the net weight is approx. 5–12 kg and the gross weight approx. 15.5–25 kg. It needs a level, stable working surface. These values are preliminary estimates; final values are confirmed against the approved drawing and nameplate.
What warranty comes with it?
A one-year manufacturer warranty.
Where can I buy the TLI TXL-GEN-010 viscometer in India?
Multiflo Instruments, based in Navi Mumbai, supplies TLI TexLab Instruments in India. Our team can advise on the TLI TXL-GEN-010 viscometer, send a quotation, and arrange installation, training, calibration and after-sales service. Use the Contact Us button or call +91-22-44516175.
Related viscosity and rheology instruments
Rotational Viscometer
Rheotest VISQI No 1, 5 to 70,000,000 mPas
Inline Viscometer
Sofraser MIVI and Soflux process viscometers
Basic Melt Flow Indexor
TLI MFI series ECO, AL and PRO, MFR and MVR to ISO 1133-1 and ASTM D1238
Fully Auto MFI Tester
Automatic melt flow indexer, up to 450 °C
Pourability Tester
Flow time of powders and granulates to EN ISO 6186
Surface Tensiometer
Differential bubble pressure, 1–500 dynes/cm
Get A Free Instrument Consultation!
We can suggest products to our customers to make them the leaders in their respective industries.